Duct fittings, Installation preparation – GE MONOGRAM ZV900 User Manual

Page 6

Advertising
background image

DUCT FITTINGS

Use this chart to compute
maximum permissible lengths for
duct runs to outdoors.

NOTE: Do not exceed maximum
permissible equivalent lengths!

Maximum duct length:
100 foot for 8

round duct

Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled.
The flexible metal duct should
be straight and smooth and
extended as much as possible.

DO NOT use flexible plastic
ducting.

NOTE: Any home ventilation
system, such as a ventilation hood,
may interrupt the proper flow of
combustion air and exhaust
required by fireplaces, gas
furnaces, gas water heaters and
other naturally vented systems.
To minimize the chance of
interruption of such naturally
vented systems, follow the
heating equipment manufacturer’s
guidelines and safety standards
such as those published by NFPA
and ASHRAE.

This Hood Must Use an

8

Round Duct.

5

Installation Preparation

Total

Equivalent

Quantity Equivalent

Duct Piece

Dimensions

Length*

Used

Length

Round,

1 ft.

straight

(per foot
length)

3-1/4

″ x 12″

1 ft.

3-1/4

″ x 24″

(per foot

straight

length)

8

″ round

90° elbow

15 ft.

8

″ round

45° elbow

8 ft.

3-1⁄4

″ x 12″

90° elbow

11 ft.

3-1/4

″ x 12″ or

45° elbow

6 ft.

3-1/4

″ x 12″

90° flat elbow

24 ft.

8

″ round to

3-1/4

″ x 12″

or 3-1/4

″ x 24″ transition

1 ft.

3-1/4

″ x 12″ to 8″

round transition

8 ft.

8

″ round

to 3-1/4

″ x 12″ or

transition 90° elbow

16 ft.

3-1/4

″ x 12″ to 8″ round

round transition 90° elbow 17 ft.

8

″ round

wall cap
with damper

30 ft.

3-1/4

″ x 12″ wall cap

with damper

30 ft.

8

″ round

roof cap

26 ft.

8

″ round

roof vent

26 ft.

*Actual length of straight duct plus duct fitting

equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.

Total Duct Run

Advertising