GE Triplex DVMRe 4eZT User Manual

Page 35

Advertising
background image

0150-0198H

35

DVMRe Triplex eZ

Pre Alarm Duration: The unit will record up to 5 seconds of data ahead of the alarm trigger, at the
Alarm Record Rate. Select from 0 to 5 seconds.

Alarm Record Mode: Use this option to determine how the unit will record cameras in alarm.

Exclusive: The unit records only the camera (or cameras) in alarm.

Interleaved: Alarmed cameras are recorded at a higher rate than

non-alarm cameras. The unit accomplishes this by interleaving images
of alarmed cameras between images from non-alarmed cameras in the record list. Interleaved is
the recommended mode of operation.

Example of Record Lists:

Exclusive record list for 8 cameras, Camera-4 in alarm.

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

Interleaved record list for 8 cameras, Camera-4 in alarm.

1 4 2 4 3 4 5 4 6 4 7 4 8 4 1 4

ACTIVITY Link to Event: Selecting Yes in this menu will activate the event record speed when
activity detection is present.

q

Main Menu

→ Record → Disk Maintenance

Use the Jog to select from the following options, then press the
Enter button to begin.

Delete: Delete all data from the hard disk (with the possibility of restoring it).

Undelete: Restore data that has been deleted, but not yet overwritten.

Destroy: Erase all data from the hard disk permanently, without the possibility
of restoring it
. Selecting this option brings up a confirmation dialog box.

Test: Provides access to the Disk Test Setup menu which features disk test and
monitoring options.


Disk Test Setup Menu

The Disk Test Setup menu provides several testing options including the test time, frequency, and
duration.

Disk Test: Options include Disable, Test Now, Test Periodically. The Test Periodically option runs

the Disk Test at the specified frequency. The Disk Tests run in the background and will not interfere
with normal operations.

Test Frequency in hours: From 0 to 1000 hours between tests.

Test Duration: This option is for the type of test to run; Fast or Thorough. The Thorough test will
test significantly more sectors than the Fast test. GE recommends using the Thorough test. The Fast
test can miss some disk failures.

UnDelete

Destroy

Test

Delete