LED information

LED information

The various subsystems in this server include LEDs that can assist you in troubleshooting
your system. See the following table for a description of these LEDs and the information
they provide:

LED Name

Function

Location

Color

Description

Power LED

Identify the
power state of
the system

Front panel

Green

■

Off = Power is off (or S4/S5
with ACPI)

■

On = Power is on (or S0 with
ACPI)

■

Blinking = S1 Low power
state with ACPI

ID

Aid in server
identification
from the back
panel

Front panel and
left back of
system board

Blue

On = Server identification
enabled

System
Status/Fault

Visible fault
warning

Front panel

Green or
Orange

■

On = No fault

■

Green blink = Degraded

■

Orange blink = Non-critical

■

Orange = Critical or
non-recoverable error

Drive status
(general)

Hard drive
activity and fault
status

Front panel

Green or
Orange

■

Green on = Drive initializing

■

Green blink = Drive active

■

Orange on = Drive or slot
failure

■

Orange slow blink =Drive or
slot fault predicted or rebuild
in progress

■

Orange fast blink = Drive
rebuild interrupted or
rebuild on empty slot

Drive status
(individual drives)

Drive activity and
fault status

Individual drive
carriers

Green or
Orange

■

Green blink - Drive active

■

Green and orange
alternating - Drive is on and
is rebuilding RAID, or is on
and in fault condition

■

Orange blink - Drive is off or
in fault condition

■

Unlit - Drive is inactive or no
drive installed in carrier

Memory board
LEDs (8)

Identify condition
of memory board
and DIMMs

On top of each
memory board

Green or
Orange

For location and description,
see

“Memory” on page 85

.

8510702.book Page 201 Thursday, July 7, 2005 11:21 AM