Troubleshooting, Warning – Graco Inc. Hydra-Clean 207-860 User Manual

Page 10

Advertising
background image

10

306-993

Troubleshooting

WARNING

To reduce the risk of serious injury whenever you

are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 8.

Before servicing this equipment always make sure to

relieve the pressure.

Note: Check all possible problems and solutions

before disassembling.

Problem

Cause

Solution

Excessive surge at spray nozzle

Obstructed spray tip, valve, or hose

Clean, clear

Excessive surge at spray nozzle

Cleaning solution supply empty

Refill

Clogged intake filter, kinked or col-

lapsed suction hose

Clean, unkink

Fluid leaking from valve

Loose packing nut or worn packings

See manual 307–010

Valve will not stop dispensing

Valve not adjusted properly

See manual 307–010

Valve will not stop dispensing

Dirty or worn valve stem or seat

Clean, clear, or replace – See manual

307–010

Valve will not stop the pump

Cleaning solution supply empty

Refill

Valve will not stop the pump

Clogged intake filter, kinked or col-

lapsed suction hose

Clean, unkink

Dirty or worn valve stem or seat

Clean clear, or replace – See manual

307–010

Dirty or worn fluid piston or packings

Service – See pump manual

Pump operating, but spray pres-

sure low on up stroke.

Dirty or worn fluid piston or packings

Service – See pump manual

Pump operating, but spray pres-

sure low on down stroke

Dirty or worn fluid intake valve

Clean, clear, or replace – See pump

manual

Pump operating, but spray pres-

sure low on both strokes

Clogged intake filter, kinked or col-

lapsed suction hose

Clean, unkink

sure low on both strokes

Dirty or worn fluid piston or packings

Service – See pump manual

Dirty or worn fluid intake valve

Clean, clear, or replace – See pump

manual

Loose packing nut or worn packings

Tighten, replace – See pump manual

Fluid will not come from pump

(hose removed)

Restricted air line

Check for closed valve; use larger

supply hose

(hose removed)

Pump throat packing nut too tight

Loosen

Pump air motor not working

Service – See pump manual

System will not spray

Restricted air line

Check for closed valve; use larger

supply hose

Pump air motor not working

Service – See pump manual