Operation, Warning, Caution – Graco Inc. Hydra-Clean 207-860 User Manual

Page 9

Advertising
background image

9

306-993

Operation

WARNING

To avoid serious injury, including fluid injection and

splashing in the eyes or on the skin, never point the

gun at yourself or anyone else.

Before Using

See Fig. 2. Prepare cleaning solution as instructed,

observing all safety precautions. Pre-mix powered

cleaners in a separate bucket of hot water before

adding to water in the supply drum.

WARNING

Take care not to get spray containing cleaning

chemicals into your eyes, ears, or nose. If any

spray does get on your skin or in your eyes, flush

immediately and thoroughly with water. Seek

immediate medical attention.

Open the bleed–type air valve (M), hold the spray

valve trigger (T) open and slowly open the pump air

bleed valve (H) until the pump is running slowly. After

solution is coming from the spray nozzle, open the

pump air bleed valve all the way and adjust the air line

lubricator (G) to deliver about 1 drop per minute. Refer

to the separate lubricator instruction manual.

Release the spray valve trigger and let the pump run.

NOTE: Protect surfaces that might be damaged by the

cleaning solution and rinse off before the solution

dries. For removing stubborn dirt, use a strong, heated

solution.

Useful Hints

WARNING

To reduce the risk of serious injury whenever you

are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 8.

Hold the spray nozzle about 2 feet (0.6 m) from the

surface you are cleaning and mist-wet it completely.

Let it soak briefly, then use the spray to “chisel” the dirt

off. Keep the nozzle at an angle, about 6 in. (150 mm)

from the surface. If some dirt remains, wet the surface

again. Let the object soak a little longer, then hold the

nozzle as close as possible and spray to blast the dirt

off.

After the dirt is removed, through rinse off the remain-

ing solution with clear, cold water. When you are done

cleaning, close the pump air bleed valve and

relieve

the pressure.

Shutdown and Care of Unit

CAUTION

To reduce the risk of damaging your pump. never

allow the pump to run dry of fluid. Keep liquid in the

container to prevent the pump from running away.

WARNING

To reduce the risk of serious injury whenever you

are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 8.

When shutting down for the day or weekend, shut off

both the bleed–type air valve and pump air bleed

valve.

Relieve the pressure. Rinse off any solution

remaining on equipment with clear, cold water. Shut off

the water supply valve and relieve the water pressure.

After shutdown, check the air line lubricator (G) often

and keep it filled with oil. Also check the pump packing

nut regularly and keep it just tight enough to stop

leakage, but no tighter. Use a 1/4 in. diameter rod to

tighten.

Advertising