306-993

Setup

Grounding

WARNING

FIRE AND EXPLOSION HAZARD

Before operating the pump, ground the

system as explained below. Also read

the section

FIRE OR EXPLOSION

HAZARD on page 4.

Although water generally provides a natural electrical

ground, the following equipment must be grounded if

the cleaning chemical are volatile.

1.

When cleaning in enclosed areas, such as storage

tanks, locate the pump and air compressor outside

the area and well away from it. Provide adequate

ventilation. If the area you are cleaning has stored

flammable materials. take appropriate precautions

to avoid static sparking. Consult your local codes.

2.

Pump: use a ground wire and clamp. See Fig. 1.

Loosen the grounding lug locknut (W) and washer

(X). Insert one end of a 1.5 mm@ (12 ga) minimum

ground wire (Y) into the slot in lug (Z) and tighten

the locknut securely. Connect the other end of the

wire to a true earth ground. Order Part No.

237–569 Ground Wire and Clamp.

Fig. 1

W

X

Y

Z

0864

3.

Air and fluid hoses: use only electrically conductive

hoses.

4.

Air compressor: follow manufacturer’s recommen-

dations.

5.

Spray gun: ground through connection to a prop-

erly grounded fluid hose and pump.

6.

Fluid supply container: follow your local code.

7.

Object being sprayed: follow your local code.

8.

Solvent pails used when flushing: follow your local

code. Use only metal pails, which are conductive,

placed on a grounded surface. Do not place the

pail on a nonconductive surface, such as paper or

cardboard, which interrupts the grounding continu-

ity.

9.

To maintain grounding continuity when flushing or

relieving pressure, hold a metal part of the spray

gun firmly to the side of a grounded

metal pail,

then trigger the gun.

General Information

The typical setup shown in Figure 2 is only a guide to

selecting and installing required and optional compo-

nents. For assistance in designing a system to suit

your needs, contact your Graco representative. Refer

to Figure 2 for callouts in parentheses.