306-993

Operation

General Information

The following instructions are for operation of the

Monark 5:1 Ratio Hydra–Clean Pressure Washers

Model 205–985 and Model 207–860. Callouts in

parentheses refer to Figure 2.

Pressure Relief Procedure

WARNING

INJECTION HAZARD

Fluid under high pressure can be in-

jected through the skin and cause

serious injury. To reduce the risk of an

injury from injection, splashing fluid, or moving

parts, follow the

Pressure Relief Procedure

whenever you:
D are instructed to relieve the pressure,
D stop spraying,
D check or service any of the system equipment,
D or install or clean the spray nozzles.

1. Lock the gun trigger safety.

2. Close the bleed-type master air valve (H, required

in your system)

3. Unlock the gun trigger safety.

4. Hold a metal part of the gun firmly to the side of a

grounded metal pail, and trigger the gun to relieve

pressure

5. Lock the gun trigger safety.

6. Open the drain valve (R, required in your system),

having a container ready to catch the drainage.

7. Leave the drain valve open until you are ready to

spray again.

If you suspect that the spray tip or hose is completely

clogged, or that pressure has not been fully relieved

after following the steps above, very slowly loosen the

tip guard retaining nut or hose end coupling and relieve

pressure gradually, then loosen completely. Now clear

the tip or hose.