Service, Warning – Graco Inc. Hydra-Clean 207-860 User Manual

Page 11

Advertising
background image

11

306-993

Service

General

WARNING

To reduce the risk of serious injury whenever you

are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 8.

See Parts illustration for referenced items. Shut off the

air supply to the pump and

relieve the pressure.

Check the air line lubricator often and keep it filled with

oil. Also check the pump packing nut regularly to keep

it just tight enough to stop leakage, but no tighter. Use

a 1/4 in. (6.3 mm) diameter rod to tighten.

To manually lubricate the motor, disconnect the air line

at the motor and place 10 to 15 drops of oil in the inlet.

Reconnect the air line and turn on the air to blow oil

into the motor. Shut off the air supply to the pump and

relieve the pressure.

Proper packing nut take-up will stop leakage. However,

all the packings should be replaced after 1000 hours

of operation or delivery of 120,000 gallons of solution

at 2 gpm. Refer to separate pump manual.

Clean the air line filter regularly.

Remove the inlet filter (2) daily and clean it. Check it

for damage that may allow contaminants to enter the

pump, and replace if necessary.

Refer to the separate instruction manuals supplied with

the components of your system for complete trouble-

shooting and service instructions.