Setup, Caution – Graco Inc. Hydra-Clean 207-860 User Manual

Page 6

Advertising
background image

6

306-993

Setup

Connect Hoses and Mount Pump

Connect hoses and pump as follows:

NOTE: This pump is supplied with a bracket (D) which

holds it to the side of a drum. If you want to install the

pump on a wall, do not install the hanging bracket. Use

Graco Wall Mounting Bracket 206–778 or equivalent

for wall setup.

1. Screw the hose stud (A) of the suction hose (B)

into the pump’s intake housing (C) using LoctiteR

Pipe Sealant. Assemble the hanging bracket (D) to

the pump with the screw, lockwasher, and nut (E)

provided.

2. Remove the ball valve (17, see Parts) from Model

205–985. It is not used in this setup. Hang the

pump on your empty cleaning solution drum.

NOTE: A pump runaway valve (F) may be installed

near the pump air inlet. This valve senses when the

pump is running too fast and shuts off the air to the

pump.

3. Connect the air line lubricator (G) to the pump air

inlet using pipe sealant. Install a pump air bleed

valve (H) and air regulator and gauge (J) to the air

line lubricator. Connect an air line filter (K) to the

regulator. From the air line filter, install an air drain

valve (L), bleed–type air valve (M), and connect to

the air supply using electrical conductive air supply

hose (N).

4. Close to the pump’s 1/2 npt(f) fluid outlet, install a

tee (P) and a fluid drain valve (R). Then install a

fluid hose (S) and Hydra–Clean gun (T). The hose

and gun are supplied with Model 205–985, but

must be purchased separately for Model 207–860.

CAUTION

Oils containing phosphate ester or chlorinated hydro-

carbons are not compatible with the plastic bowl of

the lubricator – be sure that oil used to lubricate the

compressor is free of these additives.