1.5 TOP FLUE UP & OUT WITH ADDITIONAL

BEND

Any additional bend may be used on the horizontal section

(either 45° or 90°) but the overall horizontal flue run will be

reduced.
Refer to diagram 4.

1.6 TOP FLUE VERTICAL KIT (8524/8524AN) -

ALL APPLIANCES

Vertical from the top of the appliance. (See diagram 5). A

minimum vertical rise of 3m (9'10") to a maximum of 10m

(32'10")

The basic kit comprises:
2 x 1m lengths
1 x 1m terminal lengths
1 x 52mm restrictor
1 x 47mm restrictor

Extra lengths may be added (see section 1.5), with reference

to diagram 4 and the installation instructions of the

appliance.
Refer to Table A under 3.3, Installation to identify when to

use each restrictor.

1.7 TOP FLUE VERTICAL OFFSET KIT

(8530/8530AN) – ALL APPLIANCES

Used with kit 8524 only, (see diagram 5). A minimum rise of

500mm (191/2") is required to the first bend.

1.8 OPTIONAL EXTRA FLUE LENGTHS &

BENDS

Nominal

Actual

Stainless

Anthracite

Length

Length

Finish

Finish

200mm

140mm

8527

8527AN

500mm

440mm

8528

8528AN

1000mm

940mm

8529

8529AN

45° Bend

N/A

8507

8507AN

90° Bend

N/A

8508

8508AN

Optional Flue Collar

N/A

8548

(Stoves Only)