3.2.6 To determine the length of the terminal flue section measure

from the outside of the wall to the stop on the 90° elbow.

Horizontal flue sections may fitted between the elbow and

the terminal section. See diagram 12.

3.2.7 Once the length of the terminal has been obtained, mark

the flue all the way round, insert the cardboard fitment as

shown in diagram 13. This will support the inner flue. When

cutting take care not to damage the edges of the flue. File

any sharp edges from the cut end of the flue.

REMOVE ANY CARDBOARD FITMENT REMAINING.

3.2.8 Remove the stove and flue assembly from the hearth and

drill the four fixing holes for the wall plate, insert the

rawlplugs supplied. Assemble the horizontal flue onto the

elbow and reposition the stove ensuring the flue slides

smoothly through the wall. alternatively, place the flue

terminal in the wall, place the stove on the hearth and

connect the flue to the elbow. Reposition the stove.

3.2.9 Fix the wall plate to the wall using the four black screws

provided. Drill through the fixing tab of the wall plate using

a 3.5mm drill and secure with the screw provided. Make

good and weatherproof around the outside of the flue.

3.3 TOP EXIT - VERTICAL FLUE

3.3.1 If a vertical only flue system has been purchased refer to

Site Requirements, Diagram 5.
The following areas need careful consideration:-
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all of the above, local and national codes of practice

must be adhered to.

TABLE A - TOP EXIT – VERTICAL ONLY,

INCLUDING OFFSET

Vertical Height

Restrictor Size

From Floor

3,000mm to 4,990mm

52mm Ø

5,000mm to 10,000mm

47mm Ø

Flue temp

400°C

4. HANDLING & DISPOSAL OF FIRE CERAMICS

The fuel effect and side panels in this appliance are made

from Refractory Ceramic Fibre (RCF), a material which is

commonly used for this application.
Protective clothing is not required when handling these

articles, but we recommend you follow normal hygiene rules

of not smoking, eating or drinking in the work area and

always wash your hands before eating or drinking.
To ensure that the release of RCF fibres are kept to a

minimum, during installation and servicing a HEPA filtered

vacuum is recommended to remove any dust accumulated

in and around the appliance before and after working on it.

When servicing the appliance it is recommended that the

replaced items are not broken up, but are sealed within

heavy duty polythene bags and labelled as RCF waste.
RCF waste is classed as stable, non-reactive hazardous waste

and may be disposed of at a licensed landfill site.
Excessive exposure to these materials may cause temporary

irritation to eyes, skin and respiratory tract; wash hands

thoroughly after handling the material.