Installation instructions, Site requirements – Stovax Ceramica Manhattan Wood Stove User Manual

Page 9

Advertising
background image

9

1.2 REAR FLUE 8526

Terminal dimensions:

395 x 200 x 200 mm (H x W x D)

Cut to length as required on site.

Guard Supplied.

1.3 TOP EXIT

Two types of top exit flue terminal are available, horizontal

and vertical. For a horizontal terminal, decide on the

terminal position and measure the height from the top of the

appliance to the centre of the required hole. For minimum

and maximum flue dimensions see diagram 3.
Access must be either above or at the side of the installation

to allow the flue to be assembled on top of the appliance.

When a horizontal terminal is used, the vertical sections are

assembled first, then the 90-degree elbow and finally the

horizontal section including the terminal. If a masonry

installation is to be built, a suitable lintel must be used to

support the opening.
Only the horizontal terminal section can be reduced in size.
Refer to Balanced Flue Technical Information for details of

flue length.

1.4 TOP FLUE UP & OUT KIT (8523/8523AN)

Vertical from the top of the appliance then horizontally out.

(See diagram 3.)

The basic kit comprises:
1 x 500mm vertical length
1 x 500mm terminal length (cut to length on site)
1 x 90 degree elbow
1 x wall plate
1 x 75mm restrictor fixing screws

The kit is the minimum required. Extra lengths may be

added to the vertical and horizontal (see section 1.5), with

reference to Diagram 3.
Extra lengths may be added (see section 1.5), with reference

to diagram 3 and the installation instructions of the

appliance.

Refer to Table A under 3.2, Installation for identifying when

to use the restrictor.

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

2

AR0630

3

AR1619

Advertising