Installation instructions, 12 remove duct knockout(s), For horizontal discharge installations only – GE JV635 User Manual

Page 12: For 3

Advertising
background image

Ties

12

REMOVE DUCT KNOCKOUT(S)

If recirculating, non-vented ductless (optional for
JV5 Series models only), see note below and skip to
Step 12 D and proceed

. We do not recommend the

recirculated configuration for JV6 Series models.
Using a flat blade screwdriver, remove the appropriate
duct knockout(s)

from the top or back of the hood.

3

1

4

x 10Rectangular

vertical discharge.
Remove top rectangular
duct knockout only.

7

Round vertical

discharge. Remove semi-
circular duct knockout and top
rectangular duct knockout.

3

1

4

x 10Rectangular

horizontal discharge. Remove
rear rectangular duct knockout only.

FOR HORIZONTAL DISCHARGE
INSTALLATIONS ONLY:

Remove the plate (on models so equipped) in front
of the horizontal discharge knockout. Cut the ties,
lift plate out and discard plate. DO NOT REMOVE
the metal strip held in place with two screws.

Metal strip

Plate

FOR 3

1

4

X 10RECTANGULAR

DUCTED DISCHARGE
INSTALLATIONS ONLY:

Attach exhaust adaptor/damper over knockout
opening with two exhaust adaptor screws. Make sure
damper pivot is nearest to top/back edge of hood.
Remove tape from damper flap.

Up to 1

″ side-to-

side adjustment

Tape

Top/back edge

Exhaust adaptor/damper
(vertical discharge position
shown)

Pivot

FOR 7

ROUND VERTICAL

DUCTED DISCHARGE
INSTALLATIONS ONLY:

Re-install the 7

round exhaust adaptor with its

screws, removed in Step 2 under the “Prepare the
Hood” section.

8

9

10

11

7

″ round

exhaust
adaptor

NOTE:

The 7

″ round exhaust adaptor can be installed

up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-center
installations, one end of the duct connector may need
to be trimmed to clear the electrical cable clamp.

NOTE:

The 7

″ round damper is not included with

this product. It can be purchased as a kit by calling
800.626.2002. Order kit number JXDA23.

Installation Instructions

Screw

NOTE:

The exhaust adaptor/damper can be installed

up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-
center installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.

NOTE:

If the hood is to be installed in a recirculating,

non-vented ductless manner, order charcoal filters,
kit number WB02X10707 for 30

hood models or

kit number WB02X10708 for 36

hood models.

These kits can be ordered from your GE supplier.
Skip to Step 12 D and proceed

.