Warning, Fcc and ic certified, Roubleshooting – Genie 3630436275 User Manual

Page 10: Uide

Advertising
background image

10

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

A Monthly:

Door springs and door hardware:

– Oil door roller, bearings, and hinges using silicone

lubricant or light oil .

Balance Door .

– Close door .

– Release Magnetic Carriage Assembly from Rail Assembly

by pulling down on Emergency Release Knob .

– Raise door manually 3’- 4’ and verify that door stays at

that position . See Check Step 2 on page 4 .

Reattach Magnetic Carriage Assembly to Rail Assembly by

pulling the Emergency Release Knob toward Power Head .

– Close door .

• Contact Reverse Test.

– Perform Adjustment 2 on page 8 .

NOTE

When the door is 3’ - 4’ above the ground, the door

should stay open . Slight movement is acceptable . If

the door moves too much, contact a Genie Factory

Authorized Dealer for service or call Customer Service at

1-800-35-GENIE.

WARNING

Do not operate door automatically or manually if springs

are broken . Contact a Genie Factory Authorized Dealer for

service or call Customer Service at 1-800-35-GENIE .

MAINTENANCE

B Yearly:
Wipe off old excess lubricant from Drive Screw .

Lubricate Drive Screw with Genie Lubricant (GLU-3)

WARNING

If the door fails to reverse on contact with the board,

adjust the Close Force Control as specified in Set Limit

Switches and Force Controls on page 7 . If the Opener still

fails, contact a Genie Factory Authorized Dealer for service

or call Customer Service at 1-800-35-GENIE .

NOTE

Use ONLY Genie Lubricant (GLU-3) . Other lubricants

may damage the Opener .

FCC AND IC CERTIFIED

All devices comply with Part 15 of the FCC Rules .

Operation is subject to the following two conditions: (1)

this device may not cause harmful interference, and (2)

this device must accept any interference received, includ-

ing interference that may cause undesired operation .

Screw Drive Garage

Part N

o. GLU

-3

Door Opener Lubricant

GLU-3
Lubricant

t

RoubleShootiNG

G

uiDe

Safe-T-Beam® System Self-Diagnostic Troubleshooting

Source (Red LED)

Sensor (Green LED)

Possible Problem

Solution

ON

ON

Normal operation

None required

OFF

OFF

• Power Head not powered

• Check breakers, fuses, plugs

• Wiring from Power Head bad

• Check wiring for obvious shorts


OFF

ON

• Wiring to Source missing or bad • Check wiring

• Power has been interrupted

• Remove power and reapply

2 BLINKS, Pause

• Beam not aligned

• Check Source, Sensor alignment

(Repeat)

ON

• Beam obstructed

• Check for obstruction

• Sensor defective

• Contact Customer Service

2 BLINKS, Pause

• Wire to Sensor missing or bad

• Check wiring

(Repeat)

OFF

• Sensor defective

• Contact Customer Service

3 BLINKS, Pause

• Sensor receiving interference

• Determine source of interference

(Repeat)

ON

• Contact Customer Service

4 BLINKS, Pause

• Source not sending pulses

• Contact Customer Service

(Repeat)

ON

• Source defective

• Contact Customer Service

Advertising