Door Center Line

Figure 5 Check Power Head location

11’

Grounded

outlet

10’

(7’-6” door)

(8’ door)

5

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

C

Check wall for a stud or a solid header at your mark: (If checking a

finished wall, a stud finder may be helpful) .

If location is above Header, a 2” x 6” board must be

screwed to studs beside your mark with at least two Lag

Screws and Flat Washers (not provided) .

Transfer your mark to new mounting board .

WARNING:

Door springs are under extremely high tension and

should be handled ONLY by a trained professional .

NOTE

For all types and styles of doors:

– If the ceiling in your garage is so low that there is

not at least a 3” space above the Header Bracket

mounting point, contact a Genie Factory

Authorized Dealer .

If a door spring is in the way, place the Header Bracket

above the spring . Do Not move the door spring .

C

heCk

p

oweR

h

eaD

m

ouNtiNG

a

Rea

Check Step 5:

Figure 6B Mounting methods for open beam or finished ceilings

FINISHED CEILINGS

Locate ceiling joists or trusses using

a stud finder or similar device .
Attach angle iron(not included) to

joists or trusses through finish

material using Lag Screws .

55 11

30

30

55 11

30

Perforated Straps

C

heCk

C

eiliNG

foR

G

RouNDeD

p

oweR

S

ouRCe

Check Step 6:

NOTE

Permanent wiring must be installed by a Licensed

Electrician . Not all Genie Factory Authorized Dealers

are Licensed Electrician’s . Contact someone who is a

Licensed Electrician .

WARNING:

Do Not use an extension cord! Extension cords can

cause dangerous overheating conditions .

Do Not use portable generator! This product is

designed to operate using standard house current .

Do Not use alternate power supplies,

A Check that there is a 15 Amp 120 Volt grounded electrical

outlet or grounded permanent wiring box (per building code)

within 3’ of Opener Power Head: Figure 5

If not, an outlet or wiring box must be installed . Contact

a licensed electrician for installation .

If building codes require permanent wiring, Power Head

must be partially disassembled to install appropriate

wiring in place of Power Cord . (See Assembly and

Installation Poster .)

C

heCk

S

afe

-t-b

eam

®

m

ouNtiNG

b

RaCket

l

oCatioN

Check Step 7:

Check for wood garage frame, jamb, or masonry at mounting
location (6” above floor) with attachment tabs facing away
from garage door (Figure 7) .

A If you cannot mount Safe-T-Beam® Mounting Bracket to
wood frame:

Concrete screws and concrete anchors (not included)

must be used to mount Brackets on masonry with

attachment tabs facing away from garage door .

Source

Sensor

Safe-T-Beam®

Mounting Bracket

Top of

Bracket

6” above

floor

Figure 7 Mounting

Safe-T-Beam®

Components

Check ceiling or space above where Opener Power Head will be
mounted (Figure 5): There must be a 120 Volt grounded outlet or
wiring box within 3 feet of Power Head .

A The measurements above are taken from the garage door
centerline toward the rear of the garage .
B Find location of ceiling joist or truss above where Opener Power
Head will be and estimate type and quantity of materials needed for
your installation (Figure 6A & B) .

MOUNTING EXAMPLES

Perforated Angle

Iron

Figure 6A

Standard Straps

Extra wood required

OPEN CEILINGS Straps and angle iron may attach directly to joists

or trusses .

Advertising