General Troubleshooting (Always Check the Status LED Light)

Problem

What To Do

Opener does not run

1 . Check power source .

from Remote Control

A . If Opener is connected to an outlet

:

Plug a working lamp into outlet used for Power Head .

If lamp glows, power source and outlet are OK .

If not, check fuse or circuit breaker or non-compatible GFCI .

NOTE: A licensed electrician must replace non-compatible GFCI’s.

B . If Opener is connected to a wiring box:

Check that fuse is not blown, or circuit breaker is on and not tripped or off .

If still no power, have a licensed electrician check circuit and wiring .

2 . If Power Source is OK

:

Check Power Head Terminal connections (Wall Console Installation on Assembly & Installation Poster), tighten if loose .

Check

connections at Wall Console Terminals, tighten any loose connections .

Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive

Board is properly connected to Connectors on Circuit Boards, or call Customer Service at 1-800-35-GENIE .

Door Opener starts

Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires) .

for no apparent reason

Replace any shorting Staples and shorted Wires .

Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory

and reprogram for remaining remote controls . (See Erase All Receiver Memory on page 8) .

Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls .

Door starts down, then

Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 7) .

stops before it is

Adjust as needed .

completely closed

Check for shorted Wires .

Check garage door for binding .

Door starts down, then

If a new installation, check Door Arm position .

stops and goes back up

Check operation of Contact Reverse function .

Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses .

Check Safe-T-Beam® System diagnostic code .

Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7) . Adjust as needed .

Check garage door for binding .

Door will only run closed

Check Open Limit Switch for a short circuit and for proper wiring .

Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7) . Adjust as needed .

Check condition of garage door and door spring(s) .

WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie

Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE .

Door will only run open

Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart

(see Safe-T-Beam® System Self-diagnostic Troubleshooting Section on page 13) .

Check Close Limit Switch for a short circuit and for proper wiring .

Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7) . Adjust as needed .

Lights will not go out

Disconnect Wires connected to Wall Console . (Wall Console Installation on Assembly & Installation Poster) .

Check their condition and either replace or reconnect .

Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls

or Wireless Keypad to operate Opener .

Door starts up, but stops

Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly

before it is

balanced as detailed in Maintenance Section .

completely open

WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie

Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE .

Check Open Limit Switch for a short circuit and for proper wiring .

Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7) . Adjust as needed .

Operator runs, but door

Ensure Magnetic Carriage Assembly is engaged to Rail Drive Screw (see Install Magnetic Carriage Assembly

does not move

onto Rails on page 10) .

Check Force adjustment (see Set Limit Switches and Force Controls on page 7) . Adjust as needed .

Check that all sections of Rail Drive Screw are turning when Motor runs . If not:

– Check condition (not cracked, split, or broken) and placement of Coupler . Replace as needed .

– Check condition (not cracked, split, or broken) and placement of Collar and Clip . Replace them

as needed .

Wall Console Vacation

Ensure Magnetic Carriage Assembly is in contact with Close Limit Switch .

Lock function does

Check when door is fully closed, that Carriage activates Close Limit Switch . If not, adjust position of Close

not work

Limit Switch (See page 7) .