GE E4LE User Manual

Page 31

Advertising
background image

26

POSSIBLE CAUSE

Pressurized storage switch or

float switch has cut power to

machine

Fluid temperature higher than

100F (38C) or thermal overload

in motor

No power to machine

Motor and/or pump not

operating properly

Alarm condition has turned

machine OFF

Motor starter overloaded, heater

tripped

Timing relay defective/burned

out

PROBLEM

Switch ON, unit not

operating

Deluxe (DLX) electrical

machine shutdown

SOLUTION

Check the permeate back pressure

or position of float in the storage

tank.

Allow the machine to cool; check

the feed water supply and/or amp

draw to the motor.

Check the fuses or circuit breakers,

measure the voltage.

See the pump instructions. Contact
GE Infrastructure for possible repair

or replacement.

Restart the machine by pushing the

alarm bypass. Check all possible

alarm conditions: inlet pressure or

motor starter overload

Turn the switch OFF. Rest the

heater(s). Check the motor amp

draw and the line voltage.

Replace the relay.

T R O U B L E S H O O T I N G G U I D E