2.7

Pressure Correction Factors

It is often necessary to operate RO machines with permeate back pressure. Permeate
back pressure will decrease permeate production. See Table 2.3 (Pressure Correction
Factors) to calculate loss of permeate.

Table 2.3

Pressure Correction

Factors

WARNING:

IF PERMEATE BACK PRESSURE EXCEEDS 60 PSIG (4.1 BARG)
MACHINE DAMAGE MAY OCCUR.

WARNING:

INSTALLING A CHECK VALVE WILL PREVENT REVERSE FLOW
THROUGH THE MEMBRANE ELEMENT WHEN THE MACHINE IS NOT
IN OPERATION. REVERSE FLOW, WHEN THE MACHINE IS NOT IN
OPERATION, CAN SEVERELY DAMAGE THE MEMBRANE ELEMENTS.

4

BACK PRESSURE

10 psig (0.7 barg)

20 psig (1.4 barg)

30 psig (2.0 barg)

40 psig (2.7 barg)

50 psig (3.4 barg)

60 psig (4.1 barg)

% LOSS OF

PERMEATE FLOW

E4/EZ4

E4LE

5%

10%

10%

20%

15%

30%

20%

40%

25%

50%

30%

60%

PRESSURE

CORRECTION

FACTOR (PCF)

E4/EZ4

E4LE

0.95

0.90

0.90

0.80

0.80

0.70

0.70

0.60

0.60

0.50

0.50

0.40