Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB User Manual

Page 21

Advertising
background image

DO

N

O

T

S

E

L

E

C

T

T

O

T

H

E

L

E

F

T

O

F

T

H

IS

S

Y

S

T

E

M

C

U

R

V

E

1350

Static Pr

essur

e (in. wg)

Static Pr

essur

e (Pa)

Volume (cfm)

3

Volume (m /hr )

RPM

(Belt)

RPM

(Direct)

RPM

(Vari-Green)

HP

Density 0.075 lb/ft

3

Density 1.2 kg/m

3

21

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects
of a birdscreen. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: free inlet hemispherical sone levels.

Motor HP

Fan

RPM

Static Pressure in Inches wg

Belt

Direct

0

0.125

0.25

0.375

0.5

0.625

0.75

0.875

1

1.25

101

103

1/4

VG-

1/4

720

CFM

610

477

BHP

0.02

0.02

Sones

3.8

2.7

C-1/8

860

CFM

729

623

473

BHP

0.03

0.04

0.04

Sones

4.6

3.7

2.9

1000

CFM

848

753

654

481

BHP

0.05

0.05

0.06

0.05

Sones

5.5

4.8

4.4

3.4

B-1/6

1140

CFM

966

883

805

702

507

BHP

0.07

0.08

0.09

0.09

0.08

Sones

6.6

6.0

5.7

5.2

4.1

1245

CFM

1055

978

908

824

715

BHP

0.10

0.10

0.11

0.11

0.11

Sones

7.5

7.0

6.7

6.3

5.7

1350

CFM

1144

1073

1006

938

851

731

BHP

0.12

0.13

0.13

0.14

0.14

0.14

Sones

8.5

8.1

7.8

7.7

7.2

6.7

1450

CFM

1229

1162

1099

1041

965

878

750

BHP

0.15

0.16

0.16

0.17

0.17

0.17

0.17

Sones

9.3

9.0

8.7

8.4

8.0

7.5

6.9

1555

CFM

1318

1255

1196

1140

1079

1005

917

791

BHP

0.19

0.19

0.20

0.21

0.22

0.22

0.22

0.21

Sones

10.2

10.0

9.7

9.4

8.9

8.4

8.0

7.5

1660

CFM

1407

1348

1292

1238

1187

1122

1050

963

841

BHP

0.23

0.23

0.24

0.25

0.26

0.26

0.26

0.26

0.25

Sones

11.4

11.1

10.7

10.4

10.1

9.6

9.1

8.7

8.1

1/3

A-1/4

1725

CFM

1462

1405

1351

1298

1250

1193

1126

1052

955

BHP

0.25

0.26

0.27

0.28

0.29

0.29

0.29

0.29

0.29

Sones

12.2

11.9

11.5

11.2

10.9

10.3

10.0

9.5

9.0

1800

CFM

1525

1471

1419

1368

1321

1270

1209

1142

1065

793

BHP

0.29

0.30

0.30

0.31

0.33

0.33

0.33

0.33

0.33

0.30

Sones

13.3

12.8

12.5

12.4

12.2

11.4

10.9

10.6

10.2

9.3

Damper Size = 12 x 12

(305 x 305)

Roof Opening = 14½ x 14½

(368 x 368)

Shroud Thickness = 0.051

(1.3)

Motor Cover Thickness = 0.040

(1.0)

Curb Cap Thickness = 0.064

(1.6)

^Approximate Unit Weight G/GB = 54/61 lbs.

(24/28 kg)

All dimensions in inches (millimeters). *May be greater depending on
motor. ^Weight shown is largest cataloged Open Drip-Proof motor.

1

3

4

(44)

24

3

8

(619)

4

3

8

(111)

*23

3

4

(603)

19

(483)

MAXIMUM BHP AT A GIVEN RPM = (RPM/2593)

3

MAXIMUM RPM = 1800

TIP SPEED (ft/min) = RPM x 2.913

MAXIMUM MOTOR FRAME SIZE = 56

Roof Downblast Exhaust
Belt & Direct Drive
GB-101 • G-103

C-860

-

RPM

B-1140

-

RPM

A-1725

-

RPM

VG-1725

-

RPM

Direct Drive RPM

Advertising
This manual is related to the following products:

G