Meaning – Garland GIWOK 3.5 (SH/WO 3500) User Manual

Page 17

Advertising
background image

Part # 4521635 (03/04/08)

Page 17

4. Not valid for WOK cookers. The parameters on the CPU

can now be changed! The unit temperature and the

ambient temperature must amount to 25°C (+/- 4°C) or

77°F (+/- 39°F). Press the key [ ; ]. On the console appears

the message “please confirm”. Press the key [ ; ] again. The

CU (RTCS) sensor will now be initialized on 25°C (77°F).

The following message now appears on the monitor:

save CU sensor : 25°C

5. Set the limit of the (mains) power current. (see mains

current parameters in this section):

N

increase the limit of the mains current (+)

n

decrease the limit of the mains current (-)

The following message appears on the monitor:

linecurrent limit= .......

6. Save the limit of the (mains) power current with the key [

]. On the console appears the message “please confirm”.

Press the key [ ] again. The following message appears

on the monitor:

save linecurrent limit: .......

7. Set the pan detector (see pan detector, Section 4):

T

increase pan detector (+)

t

decrease pan detector (-)

The following message appears on the monitor:

pan detector limit= .......

8. Save the pan detector with the key [ = ].On the console

appears the message “please confirm”. Press the key [ = ]

again. The following message appears on the monitor:

save pan detector limit: .......

9. By input [ -? ] the mode of adjustment will be left. The

following message appears on the monitor:

see you again!

10 The mode for adjustment has a time-out function.

After a 10 minute period, the mode of adjustment will

automatically reset.

The adjustments are now completed and it is not possible

to make any other adjustments at this point. If further

adjustments are necessary, you will be required to start from

the beginning again!

Technical information regarding the induction cooker is

also available in real-time, in the clients mode. The following

parameters listed below can be read:

Output on the hyperterminal:

1: KK:68 CU1:22 CU2:22 B:33 --- --- F:20080

1: KK:68 CU1:22 CU2:24 B:33 --- --- F:20080

1: KK:67 CU1:22 CU2:24 B:33 --- --- F:20080

1: KK:67 CU1:22 CU2:24 B:33 --- --- F:20080

Meaning

:

1:KK:68 CU1:22 CU2:22 B:33 --- --- F:20080

CU Sensor 1 - Inside

Temperature of the coil

Active

Field

Heat Sink

Temperature

CU Sensor 2 - Outside

Temperature of the Coil Error Message

Status Message

Frequency

Board

The internal cooling fan will be activated once the heat sink

temperature rises to 70°C (158°F).