Garland GIWOK 3.5 (SH/WO 3500) User Manual

Page 9

Advertising
background image

Part # 4521635 (03/04/08)

Page 9

Measurements taken across points

shown.

SECTION 5 – MAINTENANCE/SERVICE

Maintenance work must only be completed by authorized

personnel. Before beginning any maintenance work, ensure

that all power supply is disconnected and the appliance

has had an opportunity, to cool down. It is important that

the following maintenance procedures be performed as

recommended. Such preventative maintenance measures

will extend the life of this equipment and will provide

trouble free operation. The length of time used each and

the use frequency will determine how often maintenance

is required. Every cooker must be checked at least once a

year. The following routine maintenance should and must be

completed periodically.

Fan

Function of the cooker can only be guaranteed if all

electronic components are operated within their normal

working conditions (temperatures).

• The air inlet and air outlet slots must not be blocked.

• The air filter must not be blocked by dirt or grease.

• The airducts must be free of dirt.

• The air must circulate unhindered through the heat sink

(no hindrance).

• The fan is correctly installed and in good operation.

• The heat sinks are installed correctly and in place.

Check Induction coil

• Mechanical, screw mountings (screws all tightened)?

• Coil adhesive (coil wire in place o.k.)?

• Ferrites (all mounted and in place o.k.)?

• Copper coil (wire in place o.k.)?

• Coil connections to power board ok? (Refer to the

following Figures #1 and #2 for correct and incorrect, coil

connections).

Advertising