Garland GIWOK 3.5 (SH/WO 3500) User Manual

Page 5

Advertising
background image

Part # 4521635 (03/04/08)

Page 5

Maximum tolerance of power supply

Nominal voltage +6/-10 %

Frequency

50/60 Hz

Protection class

IP X0

Min. diameter of pans

Approx. 12 cm ( 4.7” )

Max. ambient temperature: stockage

-20°C to 70°C (-4°F to 158°F)

Max. ambient temperature: function

-5 °C to 40°C (23°F to 104 °F)

Max. relative humidity of air: stockage

10 to 90 %

Max. relative humidity of air: function

30 to 90 %

SECTION 3 – OPERATION

Adjusting The Performance Rate

The performance rate is adjusted by the potentiometer

(control knob). The inductive performance depends on the

position of the potentiometer:

• Position 1 = minimum power.

• Position 9 (resp. Position 12) = maximum power.

Temperature Check

Induction coil

The temperature of the induction coil is checked by a

temperature sensor. If the coil is heated over the maximum

temperature, the heating process stops. As soon as the

coil has cooled down, the Induction unit can be re-started.

Turn the position of the control knob to “0” and then to the

required power level (See Error Message, Section 6).

Power board

The temperature of the power board is checked by a

temperature sensor. As soon as the heat sink is heated over

70°C (158°F), a cooling fan starts. A heat sink temperature of

more than 80°C (176°F) automatically reduces the power in

order to keep the induction cooker working under normal

conditions. The internal temperature of the unit is supervised

as well. The power is reduced by 50% if the temperature

reaches 75°C (167°F). As soon as the temperature reaches

90°C (194°F) the unit stops working and shows the error code

“E06” (See Error message, Section 6).

Protection Overload Current

When inappropriate pan material or magnetic objects are

detected on the heating area, the current in the induction

coil may raise excessively. In order to protect the power

board, the coil current is checked and as soon as the current

in the coil exceeds the maximum tolerance, the generator

stops and there is no further active energy exchange. The

unit can be re-started as soon as normal working conditions

are reached.