5 Menus

18

TASCAM X-9

Owner’s Manual

Function

Menu

display

Meaning Available

settings

Notes

Headphone EQ

01HP

Sets headphone EQ to
normal, high or low
boost

nOr

* (no EQ)

H

High boost

L

Low boost

HL

High and low boost

Can be performed on
both left and right menu
systems.
Takes immediate effect
before being confirmed.

Program 1 fader
start

02F1

Sets fader start for pro-
gram 1 on or off

OFF

* Fader start disabled

On

Fader start enabled

Can be performed on
both left and right menu
systems.

Program 2 fader
start

03F2

Sets fader start for pro-
gram 2 on or off

OFF

* Fader start disabled

On

Fader start enabled

Can be performed on
both left and right menu
systems.

Program 3 fader
start

04F3

Sets fader start for pro-
gram 3 on or off

OFF

* Fader start disabled

On

Fader start enabled

Can be performed on
both left and right menu
systems.

Program 4 fader
start

05F4

Sets fader start for pro-
gram 4 on or off

OFF

* Fader start disabled

On

Fader start enabled

Can be performed on
both left and right menu
systems.

Cross-fader A start

6cFA

Sets the cross-fader to
start signal A playback

OFF

Fader start disabled

On

* Cross-fader starts signal A

playback

Can be performed on
both left and right menu
systems.

Cross-fader B start

7cFb

Sets the cross-fader to
start signal B playback

OFF

Fader start disabled

On

* Cross-fader starts signal B

playback

Can be performed on
both left and right menu
systems.

Footswitch
assignment

08Ft

Sets the function of the
footswitches connected
to the X-9.

EF

* links to internal effects

(1=effect 1, 2=effect 2)

E

links to external effects (1& 2=

external)

S1

Sampler 1 (1=in, 2=out)

S2

Sampler 2 (1=in, 2=out)

CF

Crossfader (

1

on, hard A

side,

1

off, current position;

2

on, hard B side,

2

off, current

position)

Can be performed on
both left and right menu
systems.

EQ memory store

09EM

Stores currently-
selected EQ settings to
memory.

Use the left menu system for programs 1 and 3.
Use the right menu system for programs 2 and 4.
The

EQ MEMO indicator lights when

09EM

is selected

When

ENTER is first pressed, the lowest empty memory

bank number is shown. Use the dial to select a bank.
If the bank already contains a setting, the display shows

SURE

. Press

ENTER to overwrite, or any other key to

cancel.

EQ memory recall

10Er

Recalls stored EQ mem-
ory settings to current
program.

Use the left menu system for programs 1 and 3.
Use the right menu system for programs 2 and 4.
The

EQ RECALL indicator lights when

10Er

is selected

Use the dial to select a bank containing EQ memory (only
banks containing data are shown).
Press

ENTER to recall the memory.

Advertising