5 menus, Program eq q values, Meter release time – GE X-9 User Manual

Page 19: Meter peak hold time, Digital out, Program fader curve, Program fader reverse, Sampler tempo

Advertising
background image

5 Menus

TASCAM X-9

Owner’s Manual

19

Program EQ Q
values

11_E

Sets the Q value for the
EQ bands of the
selected program (see
“EQ Q setting” on
page 28
)

After pressing

ENTER to

select the menu, use the dial to
select the band (

H

=high,

M

*=mid,

L

=low) and press

ENTER.

A

low value of Q

nOr

Normal value of Q

B

high value of Q

Value changes as selection is
made. Press

ENTER to con-

firm.

Use the left menu sys-
tem for programs 1 and
3.
Use the right menu sys-
tem for programs 2 and
4.

Meter release time

12Mr

Sets the meter release
time (see “Adjusting the
output volume” on
page 16
).

nor

* Normal

SLO

Slow

Can be performed on
both left and right menu
systems.

Meter peak hold
time

13MP

Sets the meter peak
hold time (“Adjusting the
output volume” on
page 16
)

All values are in seconds

OFF

0.5
1.0

*

2.0

Can be performed on
both left and right menu
systems.

Digital out

14dI

Sets whether the signal
from the digital output is
pre- or post master
fader

nOr

* Post-fader signal

rEc

Pre-fader signal

Can be performed on
both left and right menu
systems.

Program fader
curve

15Fc

Sets the fader curve as
described and shown in
“Program fader “curve””
on page 21
.

After pressing

ENTER to

select the menu, use the dial to
select the program fader to be
set (

1

,

2

,

3

or

4

) and press

ENTER.
Select from the following:

A1

–6 dB

nOr

* –12 dB

A2

–24 dB

Press

ENTER to confirm.

Can be performed on
both left and right menu
systems.

Program fader
reverse

16Fr

Sets the fader direction
to reverse as described
in “Program fader direc-
tion” on page 21.

After pressing

ENTER to

select the menu, use the dial to
select the program fader to be
set (

1

,

2

,

3

or

4

) and press

ENTER.
Select:

NOr

* Normal

rEV

Reverse

Press

ENTER to confirm.

Can be performed on
both left and right menu
systems.

Sampler tempo

17St

Sets the sampler play-
back pitch for either
sampler 1 or sampler 2.

After pressing

ENTER to

select the menu, use the dial to
select the sampler to be set
(

S1

*, or

S2

) and press

ENTER.
Use the dial to select the value
(from -

100

to

100

) and press

ENTER to confirm.

Can be performed on
both left and right menu
systems.
When sampler data is
erased, the value is
reset to 0%.

Function

Menu

display

Meaning Available

settings

Notes

Advertising