OM-202 515 Page 16

4-7. Connecting Input Power

L1

input_2 3/96 - Ref. 144 221 / Ref. 070 399-C / 802 140

Check input voltage available at

site.
1

Input And Grounding

Conductors

2

Line Disconnect Device

See Section 4-6.
Y Always connect green wire

to supply grounding termi-

nal, never to a line terminal.

Connect black, brown, and

blue wires (L1, L2, L3) to line

terminals.

3/8 in

3/8 in

2

1

1

L2
L3

Y Always connect grounding

conductor first.

3

= GND/PE