2. setting gas/air pressure – Miller Electric UPC 838 User Manual

Page 22

Advertising
background image

OM-202 515 Page 18

1

Output Control

2

Power Switch

Place controls as indicated. Only gas/air

circuit is activated when the Power switch is

turned On with Output Control in Gas/Air Set

position.

3

Gas/Air Pressure Adjustment Knob

Pull knob and turn to adjust pressure.

Push knob in to lock setting.
Select desired cutting output with Output

Control.

5-2. Setting Gas/Air Pressure

Ref. 802 140 / Ref. 802 803-A

1

Set Controls

Turn On Gas/Air Supply

Adjust Pressure

On Unit

Select Desired Amperage

To Begin Cutting

Set UPC 838 To 80 PSI

Requires

90−150 PSI Supply

Setting Gas/Air Pressure

Place Output Control in

Gas/Air Set Position

Power Switch On

Rear of

Unit

2

3

Advertising