Booster heater/wash tank heater interlock circuit, Interlock circuit operation – Moyer Diebel 501HT User Manual

Page 15

Advertising
background image

5

Installation

Booster Heater/Wash Tank Heater Interlock Circuit

For Model 201HT, 401HT, 501HT dishwashers beginning with S/N 14236 and above.

The booster heater/wash tank heater interlock circuit removes power from the wash tank heater whenever

the booster heater contactor energizes. The illustration below shows how the booster heater contactor is

wired. The booster heater contactor is located behind the lower front access panel.

Interlock Circuit Operation

1. The dishwasher fills with water when the

main power switch on the dishwasher is turned on.

The booster heater thermostat calls for heat

which energizes the booster heater contactor.

2. The auxiliary contact on the top of the contactor

opens and removes power from the wash tank

heater.

3. When the booster heater thermostat is

satisfied, the booster heater contactor de-

energizes and the auxiliary contacts close

applying power to the wash tank heater.

4. This operation is repeated whenever the

booster thermostat calls for heat.

To booster

heater contactor

1PH

208-230VAC

To

Auxiliary

Contactor

115VAC

No power when booster

heater is connected for 1 PH

No power when booster

heater is connected for 1 PH

L1

L2

L3

N

Main Terminal Block (MTB)

Booster Heater Element

Field Conversion from Single to Three Phase Operation

(continued)

ATTENTION ELECTRICIAN:
The Main Terminal Block (MTB)
is a 4-wire

connection block which includes a current-carrying

neutral. The block can be connected for 3PH or 1PH

depending on how the booster heater is wired (

see the previous page). Refer to the diagram to the

right and connect the main incoming electric service

accordingly. The data plate on the lower front

cover of the dishwasher provides the correct power

requirements.
Contact the local authorized service agent if there

are any questions concerning the proper power

connections.

To wash

tank heater

115VAC

From

main

terminal block

115 VAC

From

main

terminal block

1 PH

208-230VAC

No power

when booster

heater is

connected for

1 PH

No power when booster

heater is connected for 1 PH

L1

L3

L1

N

L2

To booster heater

1 PH 208-230VAC

1H2

1H3

1H1

Auxiliary

Contactor

Booster Heater

Contactor