Water connections – Moyer Diebel 501HT User Manual

Page 16

Advertising
background image

6

Water Connections

1. All models have a 6 ft./1.8m flexible hot water fill hose with a 3/4" female garden hose

connector.

2. A 1/2" or larger main incoming supply line should be installed to the dishwasher.

3. A 1/2" or larger shut-off valve should be installed in the main water supply as close to the

dishwasher as possible for service.

4. All models have a built-in flow control. The incoming hot water supply pressure must be

between 25-95 psi/173-655 kPa.

5. For Models 201HT, 401HT, and 501HT:

For the 40°F/ 22°C rise booster, the hot water supply must provide a minimum of

140°F/60°C, measured at the dishwasher.

For the 70°F/39°C rise booster the hot water supply must provide a minimum of 110°F/43°C

measured at the dishwasher.

6. For Models 201HTN, 401HTN, 501HTN:

The hot water supply must provide a minimum of 180°F/82°C, measured at the dishwasher

for The incoming hot water supply line must be a 1/2" or larger.

7. Models 201LT, 501LT:

The hot water supply must provide a minimum of 140°F/60°C, measured at the dishwasher.

Installation

NOTE

Plumbing connections must comply with national, local plumbing and sanitary codes.

IMPORTANT

Make sure that the flexible water supply and drain hoses are not kinked.

Advertising