Service bulletin – Moyer Diebel 501HT User Manual

Page 74

Advertising
background image

64

Digiital Temperature Display Board - 501HT

Service Bulletin

501HTM3, UH200B April 2008

Part # 0512106

Digital

Temperature Display Board

The digital temperature display board does not control temperat

ure, and is not interfaced with the timer board.

The wash display will update every 10 seconds

The rinse display updates every 20 seconds if the temperature i

s b

elow 170°F

, and every second if the temperature is above 170°F

TEST PROCEDURE

1.

Remove the thermistor harness.

The

final

rinse and wash displays should both read “E”.

2.

Press and hold the

final

rinse display test button.

The

final rinse display

should read

179°F - 180°F

.

3.

Press and hold

the wash display test button for a

minimum

of

10 seconds

.

The

wash display

should read

140°F

.

Note:

Temperature readings while testing are displayed in °

F, even if the board is set for °C during the test mode.

4.

If both the wash and

final

rinse displays indicate

specified

temperatures, the temperature display board is operating

properl

y.

Final R

inse

Displa

y

Test Butt

on

W

ash

Displa

y

Test Butt

on

Displa

y

Selec

tor

Swit

ch

°F or °C

Fac

tor

y

U

se

Only

Input

Voltage 120V

AC

Ther

mist

or

Har

ness

Q

uick

Disc

onnec

t

Plug

Advertising