Timer Board Diagnostic Testing

Press and release the scrub/Ext Wash switch if equipped

If the green indicator light for the scrub switch flashes, the

scrub/ext wash switch works

START

SCRUB

POWER

PR

4

before testing, turn the power switch OFF and allow the machine to complete the

drain cycle.

check incoming voltages

1

Open the door

If the green cycle indicator light blinks, the dOOr sWItch and cyclE lIght work

Note: this function times out after 10 seconds

close the door

2

indicator light

POWER

SC

PRIME

START

Press and release the start sWItch

If the green cycle indicator light flashes the start switch works

3

indicator light

If one or more components do not run, see below

POWER

SC

PRIME

START

PrEss start

3 tImEs

5

fill valve

detergent pump

rinse-aid pump

drain valve opens

drain valve closes

wash pump

drain pump or sanitizer pump (if applicable)

to test the timer board and the following components, press

and release the start switch 3 times with the door closed

If the components listed below are operating properly, they

should run consecutively for a few seconds each

cONdItION

POssIblE causE/sOlutION

One of the components in step 5 does not run

check the component that did not run

the wash pump is the only component that runs

check the 4 amp fuse on the timer board

the wash pump is the only component that will

not run and the 4 amp fuse is good

check pump motor/see troubleshooting guide

None of the components run in step 5

check neutral wire/see troubleshooting guide

diagnostic testing for p/n 0712105 solid state timer board

- effective serial # W081217467 and up