Number/rev, Feb-07 date – Moyer Diebel 501HT User Manual

Page 70

Advertising
background image

60

LOW VOLTAGE SECTION

MAXIMUM OVERCURRENT

PROTECTION 40 AMPS

MINIMUM CIRCUIT AMPACITY

40 AMPS

PROTECTION 30 AMPS

MINIMUM CIRCUIT AMPACITY

MAXIMUM OVERCURRENT

30 AMPS

2 AND 5 VDC

EWL

DVC

DIAGRAM STATE

END OF CYCLE

POWER-OFF

DOOR-OPEN

WP

DP

RAP

DEP

FRV

DVO

CPS

BFS

SS

EWS

DSS

CL

POL

1

2

COMMON

0512092 REV 3

208/230 VAC

NUMBER/REV

BOOSTER HEAT

1HTR

BT

BS

26-FEB-07

DATE

HC1

PER LOCAL ELECTRICAL CODES

PS

HC1

GND

TO CUSTOMERS DISCONNECT SWITCH

115-208/230V 60HZ

TT

TS

WHTR

DP

DRAIN PUMP

CB

CIRCUIT BOARD

DVO

DRAIN VALVE OPEN

BFS

BOOSTER FILL SWITCH

FILL/RINSE VALVE
GROUND

DOOR SAFETY SWITCH

DRAIN VALVE CLOSED

GND

DVC

FRV

DSS

CYCLE LIGHT
WASH PUMP

CHEMICAL PRIME SWITCH

START SWITCH

BOOSTER CONTACTOR
BOOSTER HEATER

DETERGENT PUMP

POWER ON LIGHT

WP

SS

CPS

CL

1HTR

POL

HC1

DEP

BOOSTER SAFETY THERMOSTAT
EXTENDED WASH SWITCH
SANITIZER PUMP

SP

EWS

BS

POWER ON SWITCH
RINSE AID PUMP

TANK HEAT SAFETY THERMOSTAT

TANK HEAT THERMOSTAT

BOOSTER THERMOSTAT

TT
TS

BT

RAP

PS

EXTENDED WASH LIGHT

WASH TANK HEATER

WHTR

EWL

5 kW

Prior to S/N 14236

501HT High Temperature Digital Display

RTS

WTS

RINSE TEMPERTURE SENSOR
WASH TEMPERTURE SENSOR

WTS

RTS

GND

HC1

5 kW

BOOSTER HEAT

208/230 VAC

1HTR

208/230V+115V NEUTRAL 60HZ

21

N

L2

L1

DETERGENT

FILL/RINSE

DRAIN VALVE CLOSED

DRAIN VALVE OPEN

DRAIN PUMP (not on 501HT)

WASH PUMP

R/A

NEUTRAL

115 V

ON/OFF

BOOSTE

R

1L2

1L1

1

5

1

3

4

1L1

7

8

9

N

22

15

17

16

18

19

20

15

10

1

N

1

1H2

1H1

11

12

8

9

7

13

14

10

CB

8

7

5

6

4

3

2

1

4

3

2

1

115 V

NEUTRAL

30

31

32

33

L1

L2

N

L3

1H1

1H3

1H2

SINGLE PHASE

THREE PHASE

L2

L1

10

High Temp. - 501HT - Prior to S/N 14236

Advertising
This manual is related to the following products: