4-3. Volt-Ampere Curves

The volt-ampere curves show the

minimum and maximum voltage

and amperage output capabilities of

the welding power source. Curves

of other settings fall between the

curves shown.

.

Ranges 4, 5, and 6 apply to 230
VAC only.

ssb1.1 10/91 − 199 212

0

5

10

15

20

25

30

35

0

50

100

150

200

250

DC AMPERES

DC VOL

TS

Range 1

Range 2

Range 3

Range 4 Range 5

Range 6

4-4. MIG Welding Gun Duty Cycle And Overheating

CAUTION

WELDING LONGER THAN RATED DUTY CYCLE can damage gun and void warranty.

Do not weld at rated load longer than shown below.

Using gasless flux cored wire reduces gun duty cycle.

warn7.1 8/93

Duty Cycle is percentage of 10

minutes that gun can weld at

rated load without overheating.

Continuous Welding

SB1.1 8/93

0

10

Minutes

Definition

.023 To .045 in (0.6 To 1.1 mm)

Hard Or Flux Cored Wires

100% Duty Cycle At 100 Amperes

Using CO

2

.023 To .045 in (0.6 To 1.1 mm) Hard Or Flux Cored Wires

60% Duty Cycle At 100 Amperes

Using Mixed Gases

6 Minutes Welding

4 Minutes Resting