3. unit overload, 4. replacing gun contact tip, 5. changing drive roll and wire inlet guide – Miller Electric M-10 Gun User Manual

Page 31

Advertising
background image

OM-1330 Page 27

6-3. Unit Overload

Thermostats TP1 in rectifier SR1 and TP2 in stabilizer Z1 protect the unit from damage due to overheating. If TP1

and/or TP2 opens welding output will shut off. Wait several minutes before trying to weld.

Supplementary protector CB2 (Power switch) protects transformer T1 from overload. If CB2 opens, unit power will

shut off. Check input power supply, and press Power switch to turn unit back on.

6-4. Replacing Gun Contact Tip

Ref. 800 797-C

Y Turn Off power.
1

Nozzle

2

Contact Tip

Cut off welding wire at contact tip.

Remove nozzle.
Remove contact tip and install new

contact tip. Reinstall nozzle.

Tools Needed:

1

2

6-5. Changing Drive Roll and Wire Inlet Guide

1

Securing Screw

2

Inlet Wire Guide

Loosen screw. Slide tip as close to

drive rolls as possible without

touching. Tighten screw.
3

Drive Roll

The drive roll consists of two

different sized grooves. The

stamped markings on the end

surface of the drive roll refers to the

groove on the opposite side of the

drive roll. The groove closest to the

motor shaft is the proper groove to

thread (see Section 4-15).
Install correct drive roll for wire size

and type.
4

Drive Roll Securing Nut

Turn nut one click to secure drive

roll.

Tools Needed:

5/64 in

7/16 in

Ref. 802 990-A

1

2

3

4

Advertising
This manual is related to the following products: