Section 6 − maintenance &troubleshooting, 1. routine maintenance, 2. supplementary protector cb1 – Miller Electric M-10 Gun User Manual

Page 30

Advertising
background image

OM-1330 Page 26

SECTION 6 − MAINTENANCE &TROUBLESHOOTING

6-1. Routine Maintenance

Y Disconnect power

before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace unreadable labels

Repair or replace

cracked weld cable

Clean and tighten weld terminals

6 Months

Blow out or vacuum inside.

OR

Remove drive roll and

carrier. Apply light coat

of oil or grease to drive

motor shaft.

Ref. 802 990

6-2. Supplementary Protector CB1

1

Supplementary Protector CB1

If CB1 opens, wire feeding stops.
2

Welding Gun

Check gun liner for blockage or

kinks.
3

Wire Drive Assembly

Check for jammed wire, binding

drive gear or misaligned drive rolls.
Allow cooling period and reset

breaker. Close door.

2

Ref. 803 860-B / Ref. 802 714

3

1

Advertising