11. connecting 1-phase input power for 230 vac – Miller Electric M-10 Gun User Manual

Page 20

Advertising
background image

OM-1330 Page 16

4-11. Connecting 1-Phase Input Power For 230 VAC

803 766-B / Ref. 802 443-A

Y Installation must meet all

National and Local Codes − have

only qualified persons make this

installation.

Y Disconnect and lockout/tagout

input power before connecting

input conductors from unit.

Y Always connect green or green/

yellow conductor to supply

grounding terminal first, and never

to a line terminal.

1

Black And White Input Conductor

(L1 And L2)

2

Green Or Green/Yellow Grounding

Conductor

3

Input Power Cord.

4

Disconnect Device (switch shown in

the OFF position)

5

Disconnect Device Grounding

Terminal

6

Disconnect Device Line Terminals

Connect green or green/yellow grounding

conductor to disconnect device grounding

terminal first.
Connect input conductors L1 and L2 to

disconnect device line terminals.
7

Over-Current Protection

Select type and size of over-current

protection using Section 4-12 (fused

disconnect switch shown).
8

Receptacle (NEMA 6-50R)

Customer Supplied

Close and secure door on disconnect

device. Remove lockout/tagout device,

and place switch in the On position.

4

3

L1

L2

1

=GND/PE Earth Ground

2

1

5

6

7

Tools Needed:

L1

L2

230 VAC, 1

8

Advertising