5-2. Description Of Front Panel Controls (See Section 5-1)

Engine Starting Controls
1

Magnetic Shutdown Switch

Use switch during start-up to bypass engine

shutdown system. System stops engine if oil

pressure or fuel level is too low or coolant tem-

perature is too high.
2

Starting Aid Switch

Use switch to energize port heater for cold

weather starting (see starting instructions fol-

lowing).
3

Engine Control Switch

Use switch to start engine, select engine

speed ( if unit has auto idle option), and stop

engine.
In Run position, engine runs at weld/power

speed. In Run/Idle position (optional), engine

runs at idle speed at no load and weld speed

with load applied. Turn to run position if using

optional auxiliary power plant.
To Start:
Above 325 F: turn Engine Control switch to

Start while pressing Shutdown switch. Re-

lease switches when engine starts and en-

gine indicator lights go out. Do not crank en-

gine while engine is turning.
Below 325 F: turn engine control switch to

Run/Idle position. Press Starting Aid switch

for 60 seconds. While still pressing Starting

Aid switch, press Magnetic Shutdown switch

and turn Engine Control switch to Start. Re-

lease switches when engine starts and en-

gine indicator lights go out. Do not crank en-

gine while engine is turning.
To Stop: turn Engine Control switch to Off

position.
Engine Indicator Lights
4

Battery Charging Light (If Equipped)

Light goes on if engine alternator is not charg-

ing battery. Engine continues to run.
Y Stop engine and fix trouble if Battery

Charging light goes on.

5

Engine Temperature Light

Light goes on and engine stops if engine tem-

perature is above 221

°

F (105

°

C).

Y Stop engine and fix trouble if Engine

Temperature light goes on.

6

Engine Oil Pressure Light

Light goes on and engine stops if oil pressure

is below 10 psi (69 kPa). Light goes on mo-

mentarily during start-up but goes out when

engine reaches normal oil pressure.
Y Stop engine and fix trouble if Engine

Oil Pressure light stays on after start-

up.

7

Fuel Light

Light goes on and engine stops if fuel level is

low. Add fuel to resume operation.
8

Engine Hour Meter

Engine Gauges

.

To read gauges and engine indicator
lights with engine off, turn Engine Control

switch to Run/Idle and press Magnetic

Shutdown switch (see Section 7-8).

9

Fuel Gauge

10 Battery Voltmeter (Optional)
Use gauge to check battery voltage and moni-

tor the engine charging system. The meter

should read about 14 volts dc when the en-

gine is running, and about 12 volts dc when

the engine is stopped.
11 Engine Coolant Temperature Gauge

(Optional)

Normal temperature is 180 - 203

°

F (82 - 95

°

C). Stop engine if temperature exceeds 221

°

F (105

°

C).

12 Engine Oil Pressure Gauge (Optional)
Normal pressure is 30 − 60 psi (207 − 414

kPa). Stop engine if pressure is below 10 psi

(69 kPa).
Weld Controls

.

Max OCV Control Circuit: This unit has

a max OCV control circuit that resets Am-

perage Adjust control R1 to maximum

when the arc breaks. When an arc is

struck, weld output control returns to the

R1 front panel or combination front panel/

remote control setting. The Amperage

Adjust control adjusts amperage only

when welding and does not adjust open-

circuit voltage.

The max OCV circuit is disabled when

the Stick/TIG Selection switch is in

Scratch Start TIG position (see item 15).

13 Ampere Range Switch
Y Do not switch under load.
Use switch to select weld amperage range.

For most welding applications, use lowest

amperage range possible to help prevent arc

outages.
14 Amperage Adjust Control
Control adjusts amperage within range se-

lected by Ampere Range switch. Weld output

would be about 223 A DC with controls set as

shown (50% of 125 to 320 A).
15 Stick/TIG Selection Switch
Use switch to disable max OCV circuit for

scratch start TIG welding (see max OCV note

under Weld Controls). When switch is in Stick

position, the max OCV circuit resets Amper-

age Adjust Control R1 to maximum when the

arc breaks. When switch is in Scratch Start

TIG position, max OCV circuit is disabled and

OCV changes when the control is adjusted.

.

If Stick/TIG Selection switch is in TIG
position, turn Amperage Adjust control to

max for full output from optional auxiliary

power plant.

16 Amperage Adjust Switch And Remote

Amperage Adjust Receptacle

Connect optional remote control to RC13

(See Section 4-10). Use switch to select front

panel or remote amperage control. For re-

mote control, place switch in Remote position

and connect remote control to Remote Am-

perage Adjust receptacle RC13 (see Sec-

tions 4-10 and 5-3).
17 Polarity Switch (Optional)
Y Do not switch under load.
Use switch to change weld output. Select ei-

ther DC Electrode Positive (DCEP) or DC

Electrode Negative (DCEN).
Weld Meters
18 DC Voltmeter (Optional)
Voltmeter displays voltage at the weld output

terminals, but not necessarily the welding arc

due to resistance of cable and connections.
19 DC Ammeter (Optional)
Ammeter displays amperage output of the

unit.