3. connecting to power source, 4. input 14 pin information for receptacle rc1 – Miller Electric IH User Manual

Page 13

Advertising
background image

OM-203 185 Page 9

4-3. Connecting To Power Source

Turn Off power source.
1. IH/TS
2. Interconnecting Cord
3. 14-Socket Plug
4. 14-Pin Plug
Obtain cord with 14-socket plug on

one end and 14-pin plug on other

end.
5. Keyway
6. Remote 14 Receptacle RC1

(See Section 4-4)

To connect cord to a receptacle,

align keyway, insert plug, and

tighten threaded collar.
To connect remaining end of cord to

power source, align keyway, insert

plug, and tighten threaded collar.

2

sb7.1* 3/93 - Ref. S-0004-A / S-0750 / Ref. 802 926 / Ref. 801 049 / 801 825-B / Ref. 803 004-A

3

4

1

6

J

A

I

K

B

H N L

C

G M

D

F E

5

4-4. Input 14 Pin Information For Receptacle RC1

REMOTE 14

Pin

Pin Information

Remote Contactor

A

+24 volts dc from power source.

Remote Contactor

B

Contact closure to A completes power source +24 volts dc contactor control circuit.

Remote Output Control

D

Control circuit common.

Remote Output Control

E

0 to +10 volts dc signal for power source output control.

Power Source Fault

F, J

Absence of contact closure from power source indicates power source output failure.

I

Actual frequency input signal.

Remote Metering*

L

Average power input signal.

Remote Metering*

M

Voltage input signal RMS.

N

Current input signal RMS.

*See power source Owner’s Manual for scaling information.