Figure 6-2 and figure 6-3, Seg.n 1 type step tgt 600, Seg.n 3 type dwel dur 0.5 – Miller Electric IH User Manual

Page 27: Seg.n 4 type rmp.r tgt 600, Seg.n 5 type end end.t s op, Rate 600

Advertising
background image

OM-203 185 Page 23

Step to 600

°

F

as fast as

possible*

Ramp to 1350

°

F

@ 600

°

/hr

SEG.n

1

tYPE

StEP

tGt

600

(step)

(deg)

SEG.n

2

tYPE

rmP.r

tGt

1350

(ramp rate)

SEG.n

3

tYPE

dwEl

dur

0.5

(soak)

(in hrs)

0

200

400

600

800

1000

1200

1400

0

30

60

90

120

150

180

Time (minutes)

Degrees F

Example Stress Relief Profile

SEG.n

4

tYPE

rmP.r

tGt

600

(ramp rate)

Free fall to

ambient

SEG.n

5

tYPE

End

End.t

S OP

(end)

(sets output to 0)

rAtE

600

(deg)

(deg/ hr)

rAtE

600

(deg)

(deg/hr)

Dwell @ 1350

°

F for 1/2 hour

Ramp to 600

°

F

@ 600

°

/hr

210

240

270

.

*On small diameter pipe, it may be necessary to reduce the
output of the power source to achieve a “reasonable rate” in

Segment 1; thereafter, the program controls the rate of

temperature rise and the output power may be increased to

full if desired. To reduce output power, turn power source

output knob to desired setting.

Figure 6-2. Setting Stress Relief Profile Using Example Parameters