OM-203 185 Page 54

Trouble

Remedy

2408 Temperature Controller reads

greater than 5

°

F different than

Channel 1 on 5100V Recorder.

See Section 8-3I.

2408 Temperature Controller

readings fluctuate rather than

remain stable.

Check and secure connections to the workpiece.

5100V Recorder screen blinks

when touched, but does not

advance to next screen.

Screen calibration needs adjusting. Turn off IHTS power switch. Turn on IHTS power switch while touching

screen, and continue to touch screen (about 45 seconds) until configuration display appears on the screen.

Press “Touch Cal” or wait a few minutes for the Touch Cal display to appear on the screen. Use a pointed object

(be careful not to damage screen), and touch each set of cross hairs to calibrate screen. When calibration

is complete, turn IHTS power off and back on again.

5100V Recorder does not recognize

floppy disk

Floppy disks do not work well in ambient temperatures greater than 104

°

F (40

°

C).

floppy disk.

Clean floppy drive with a disk drive cleaner (available from a local computer reseller).