3 - AT Commands, S-Registers and Result Codes

33

Command:

&Q

n

Asynchronous Communications Mode

Values:

n = 0, 5, or 6

Defaults:

5

Description: &Q0

Asynchronous with data buffering. Same as

\N0.

&Q5

Error control with data buffering. Same as

\N3.

&Q6

Asynchronous with data buffering. Same as

\N0.

Command:

&S

n

Data Set Ready (DSR) Control

Values:

n = 0 or 1

Default:

0

Description: &S0

Force DSR high (on).

&S1

Let DSR follow CD.

Command:

&T

n

Test Commands

Values:

n = 0, 1, 3 or 6

Default:

None

Description: &T0

Abort. Stop any test in progress.

&T1

Local analog loop test.

&T3

Local digital loopback test.

&T6

Remote digital loopback test.

Command:

&V

View Current Configuration

Values:

n/a

Description:

Displays the active modem settings.

Command:

&W

n

Store Current Configuration

Values:

n = 0

Default:

None

Description: &W0

Store active modem settings in NVRAM; load them

at power-on or following the ATZ command instead
of loading the factory defaults from ROM.

Command:

&Y

n

Select Stored Configuration for Hard Reset

Values:

n = 0

Default:

0

Description: &Y0

Select stored configuration 0 on power-up. (For

backward compatibility with some software.)

Command:

&Z

n=x Store Telephone Number

Values:

n = 0, 1, 2 or 3
x = Dialing string

Default:

None

Description:

Stores telephone dial string

x in memory location

n. Dial the stored number using the command
ATDS=n.