SECTION 5 − SETTING SEQUENCE PARAMETERS

5-1.

Sequence Parameters in a Program

.

See Menu Guide for detailed
programming steps.

Trim is arc length. If set to zero, arc
length is short. If set to 99, arc
length is long.

If time is set to zero in Weld se-
quence, welding continues until
gun trigger is released.

.

Crater and Burnback do not
function in Pulse or Adaptive
Pulse.

If time is set to zero in any timed se-
quence except Weld, the sequence
is skipped.

Trigger

Pressed

Trigger

Released

Wire Speed

Time

Start

Time

Preflow

Run-In WFS

W

eld WFS

Weld Time

Crater WFS

Crater

Time

Postflow

Arc

Strike

Burnback

Time

Time

Time

Postflow

Crater

Weld

Run-In

Preflow

Burnback

Sequence

End

0 − 25 sec.

Trim
0-99

Volts
10.0-38.0

Inductance
0-99%

IPM
70-875

Seconds

1.

Weld

2.

Crater

3.

Burnback

4. & 5. Postflow/
Preflow

6.

Run-In

Pulse

MIG

Pulse

MIG

MIG

0-25.0

0-2.50

0-0.25

0-9.9

X

X

X

X

X

X

X

X

5-875

X

X

X = Setting available.

Pulse

6.

Start

Pulse

MIG

0-2.50

X

X

X

X