OM-1589 Page 39

13-5. Removing Air-Cooled Contact Tip Adapter

150 430-A

1

Barrel Extension

Remove as shown.

2

Contact Tip

3

Compression Nut

To remove, see Section 13-3.

4

Contact Tip Adapter

5

Head Tube

6

Head Tube Setscrew

Loosen setscrews and remove
adapter.

Install new adapter and tighten set-
screws. Reinstall contact tip, com-
pression nut, and nozzle.

Tools Needed:

3/32 in

1

2

3

4

6

5

13-6. Removing Water-Cooled Contact Tip Adapter

150 431

Y

Point gun downward when
removing water-cooled bar-
rel to keep water out of gun.
Wipe gun dry before putting
it back together.

1

Nozzle

2

Nozzle Adapter

Remove as shown.

3

Contact Tip Adapter

Use wrench to remove adapter.

Coat new adapter with threadlock-
ing compound (such as Loctite No.
242), and install.

Tools Needed: