OM-1589 Page 28

SECTION 8 − SYSTEM SETUP

8-1.

System Setup Display Parameters

See Menu Guide for detailed programming steps.

NOTE

Display Setting

Notes

>System *

Select the process the welding power source is able to do.

>Model *

For the Invision 456 and XMT 304 selections, pulse data and welding power source minimum and maximum voltage
values are automatically loaded in. For the “Other” selection, welding power source minimum and maximum voltage
and amperage values must be entered. Pulse data defaults to XMT 304 values.

>Access

When On, restricts use of setup screens.

>Mig Type

Default is Off. Set to On only for older CV welding power source without voltage feedback at 14-socket receptacle.

>Voltage

Default is 14-pin receptacle. Use V. Sense when more than 50 ft (15m) of weld cable is used (including gun cable
length).

>Arc Start**

Use Hot Start only with 450 Ampere Inverter Model welding power source and large diameter wires. The arc starts in
CV and switches to CC.

>Dual Schedule

See Section 6-2.

>Trigger

When on, trigger can be used to switch between programs that have at least 0.2 seconds of preflow time programmed.

>Remote

When on, a DSS-10 can be used to change Volts or Trim, IPM, or Prg depending on where the front panel display > is.

>Arc Time

Displays accumulated arc time and cycles.

>Wire Feed

Choose to display inches per minute or meters per minute and motor type, but installed motor must match selection.

>Memory

No Reset: allows operator to exit memory reset parameter without resetting any data.

Program Reset: unit defaults to original factory setting for the last active program. Setup information does not change.
If setup card is in card slot, program will be loaded from card.

System Reset: unit defaults to original factory settings for all programs and setup excluding System and Arc Time. If
setup card is in card slot, program will be loaded from card.

Total Reset: unit defaults to original factory settings for all programs and setup including System and Arc Time. If setup
card is in card slot, program will be loaded from card.

System Reset: unit defaults to original factory settings for all programs and setup excluding System, Arc Time, and
Model. If setup card is in card slot, program will be loaded from card.

>Shutdown

When on, the system immediately shuts down if no arc voltage is sensed. When Off, wire feeds even if no arc voltage
is sensed.

>Gas Flow

♦♦

Setting must be Meter Off if option is not installed.

>Ramps

Turns start and crater ramping On or Off. When On, output power is tapered from start to weld and from weld to crater.

>Software

Know this information when talking with service personnel.

* Automatically set if power source data card is used.

Can be used only when optional data card is inserted.

** Selection does not appear on display when MIG Only is System choice.

♦♦

Must remain set to Meter Off if option is not installed to prevent system error.