Rs-485 port connection – Mace DVR1604RW User Manual

Page 59

Advertising
background image

DVR1604RW

Digital Video Recorder

Operational Manual

© 2004 Mace Security Products.

59

4. RS-485 port connection

If you want to control Camera pan-tilt-zoom (P/T/Z) or activate the DVR Output relay, the 25-pin RS485

connection must be used. See detail below.

The RS485 port connection can control various (P/T/Z) Cameras, and the specific model or protocol can be

selected from the Control Menu in System settings.

The DB25 pin outs are marked below. The definition of the pin outs are as follows: The broken line in the

graph indicates inside connection

a)

Pins 1,14,2,15,3,16,4,17 connects to alarm input: ALARM1~ALARM8

b)

Pins 5 & 18 = OUTPUT Relay 1 - 6 & 19 = OUTPUT Relay 2 Each Relay (normally open):

c)

Pins 7&20 = OUTPUT 3 is a controllable +12V output.

d)

Pins 8, 9 & 21 are +12V power output, Use for Low current items only such as Relays and Alarm Devices.

e)

Pins 10 & 22 are the B line of RS485, Pins 11 & 23 are the A line of RS485;

f)

Pins 12, 13, 24 & 25 are Ground (Gnd).

Combined as RS485 B line

Combined as RS485 A line

Decoder

Decoder

A B

A B

Alarm input ALARM 1

ALARM 8

Alarm output

ALARMOUT1

ALARMOUT2

Controllable +12V output

+12V output

Gnd

120

End of Line

(EOL)

resister

required .

Advertising