4. remote 14 socket information – Miller Electric Intellifire 250 User Manual

Page 12

Advertising
background image

OM-184 227 Page 8

sb7.1* 3/93 - Ref. S-0004-A / Ref. S-0750 / Ref. ST-801 826-C

3-3. Remote 14 Receptacle RC14 Information and Connections

1

Front Panel

2

Plug

3

Threaded Collar

4

Keyway

5

Remote 14 Receptacle RC14

(See Section 3-4)

To connect to receptacle, align key-

way, insert plug, and tighten

threaded collar.

2

3

A

J

B

K

I

C L N

H

D M

G

E

F

4

5

1

3-4. Remote 14 Socket Information

Socket

Socket Information

Remote Contactor

A

+24 volts dc.

Remote Contactor

B

Contact closure to A completes 24 volts dc contactor control circuit.

C

Command reference; +10 volts dc.

Remote Output Control

D

Control circuit common.

Remote Output Control

E

Input command signal (potentiometer wiper or 0 to +10 volts dc).

G

Not used.

Power Source Limit

F, J

Absence of internal contact closure between F and J signals power source failure to remote

control device.

H

Coil loss compensation value.

H

I

p

Actual frequency output signal (1 volt/10 kHz).

Remote Metering

I

L

Average power output signal (1 volt/5 kW).

Remote Metering

M

Voltage output signal RMS (1 volt/100 volts).

N

Current output signal RMS (1 volt/100 amperes).
Ch

i

K

Chassis common.

Advertising