OM-184 227 Page 15

5-8. Diagnostic LED’s

Ref. ST-801 826-B

1

Diagnostic LED’s

Use diagnostic LED’s to determine

operating condition of power

source.
2

Current Source

Limit: 110 A
Fault: 115 A
3

Over Frequency

Limit: 50 kHz
Fault: 55 kHz
4

Under Frequency

Limit: 10 kHz
Fault: 5 kHz
5

Current

Reactive Limit: 700 A
6

Tank Voltage

Limit: 670 V
Fault: 1100 V Peak
7

Line Voltage

Fault:

±

20 %

8

Contactor

Lights when contactor is energized.
9

Over Temp

Lights when contactor is energized

and over temperature condition is

present. Also indicates top cover is

removed from unit.
10 Tank Current
Fault Value Preset At Factory
11 Ground Fault
Lights when the ground fault

circuitry detects a short in the

output circuit between the

workpiece and power source, or

when test switch is pressed to test

ground fault circuitry.
12 Load
Lights when no load or insufficient

load is present to couple with the

coil or blanket.