SECTION 5 − MAINTENANCE & TROUBLESHOOTING

5-1. Routine Maintenance

Y Disconnect power

before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Clean and tighten

output connections.

Repair or replace

cracked cables

and cords.

6 Months

Replace damaged or

unreadable labels.

Blow out or vacuum

inside.

5-2. Overheating

Thermostats TP1, TP2, and TP3 protect the unit from damage due to overheating. If one or more of the heat sinks get

too hot, TP1, TP2, and/or TP3 opens and output stops. The fan keeps running to cool the heat sink(s). Wait several

minutes before trying to heat.

5-3. Automatic Shutdown Protection

This unit automatically shuts down upon sensing certain fault conditions, such as an out-of-range frequency condition,

short circuit load condition, or an open circuit (no load) condition. The unit also has automatic voltage limiting and

power ratio limiting, which limits the output power based on improper load impedance.

Ref. ST-801 826-C

Tools Needed:

5-4. Safety Interlock Switch

1

Rear Panel

2

Safety Interlock Switch

The safety interlock switch

prevents the contactor from

energizing with the wrapper off the

unit.

3/8 in

2

1