Usable scan length, Usable scan length -8, Table 8-3 – Motorola SYMBOL MINISCAN MSXX04 User Manual

Page 102

Advertising
background image

8 - 8

Symbol MiniScan MSXX04 Series Integration Guide

Usable Scan Length

The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow
ratio, and edge accuracy. Consider the width of the scan line at any given distance when designing a system.

Calculating the Usable Scan Length Method (Symbol MS954 Only)on page 2-9

describes how to calculate the

usable scan length. The scan angle is provided in the usable scan length diagram on

page 2-9

.

Table 8-3

Symbol MS954 Decode Distances

Symbol Density/

p/n / Bar Code Type/

W-N Ratio

Bar Code Content/

Contrast

1

Typical Working Ranges

Guaranteed Working

Ranges

Near

Far

Near

Far

5 mil

64-17453-01

Code 39; 2.5:1

ABCDEFGH

90% MRD

0.7 in.

1.8 cm

7.3 in.

18.54 cm

1.6 in.

4.06 cm

4.8 in.

12.19 cm

7.5 mil

64-17452-01

Code 39; 2.5:1

ABCDEF

90% MRD

0.9 in.

2.29 cm

12.3 in.

31.24 cm

1.4 in.

3.56 cm

8.8 in.

22.35 cm

13 mil

64-05303-01

100% UPC

12345678905

90% MRD

0.9 in.

2.29 cm

22.0 in.

55.88 cm

1.1 in.

2.79 cm

15.7 in.

39.88 cm

20 mil

60-01429-01

Code 39; 2.2:1

123

90% MRD

Note 2

27.5 in.

69.85 cm

Note 2

22.0 in.

55.88 cm

40 mil

64-17457-01

Code 39; 2.2:1

AB

90% MRD

Note 2

28.0 in.

71.12 cm

Note 2

23.0 in.

58.42 cm

55 mil

64-17458-01

Code 39; 2.2:1

CD

90% MRD

Note 2

35.0 in.

88.90 cm

Note 2

29.0 in.

73.66 cm

Notes:
1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm.
2. Near ranges on lower densities (not specified) largely depend on the width of the bar code and
the scan angle.
3. Working range specifications at ambient temperature (23°C), pitch=15°, roll=0°, skew=0°,
photographic quality, ambient light<200 ft-c.