Parameter Menus 10 - 41

Convert UPC-E1 to UPC-A

Parameter # 26h

Enable this parameter to convert UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission.
After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble,
Check Digit).

Scan DO NOT CONVERT UPC-E TO UPC-A to transmit UPC-E1 (zero suppressed) decoded data.

Convert UPC-E1 To UPC-A

(Enable)

(01h)

*Do Not Convert UPC-E1 To UPC-A

(Disable)

(00h)

EAN Zero Extend

Parameter # 27h

When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them
compatible in format to EAN-13 symbols.

Disable this parameter to transmit EAN-8 symbols as is.

Enable EAN Zero Extend

(01h)

*Disable EAN Zero Extend

(00h)