Symbol ms3204 decode zones, Omnidirectional decode distances, Symbol ms3204 decode zones -8 – Motorola SYMBOL MINISCAN MSXX04 User Manual

Page 90: Omnidirectional decode distances -8

Advertising
background image

7 - 8

Symbol MiniScan MSXX04 Series Integration Guide

Symbol MS3204 Decode Zones

The decode zone is a function of various symbol characteristics including density, print contrast, wide to narrow
ratio and edge acuity. The figures shown are typical values.

Table 7-3 on page 7-9

and

Table 7-4 on page 7-11

list

the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol
density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of
a symbol at any given range is shown below. To calculate this distance, see

Calculating the Usable Scan Length

Methodon page 2-8

.

Omnidirectional Decode Distances

Figure 7-5

Symbol MS3204 Omnidirectional Decode Zone

Depth of Field

1.00

.25

In.

cm

0

20 mil

Depth of Field

12.5

2.5

5

7.5

10

12.5

0

12.7

25.4

38.1

50.8

63.5

80% UPC

12.5

6 mil

1.00

6.5

.25

3.25

100% UPC

0

cm

W

i

d

t

h

o

f

F

i

e

l

d

0

2.5 6.35

5

12.7

12.7

1.5

1.75

* Minimum distance determined by symbol length and scan angle.

2.5

5

6.35

in.

Note: Typical performance at 68˚F (20˚C)
on high quality symbols in normal room light.
Vcc = 5V

Advertising